Overview
OTDR Meter AFL OFL280
Noyes OFL-280 otdr meter is a product designed for FTTH, FTTx subscriber testing. With the ability to equip with all the features of a normal otdr plus the function of power meter, light sources, visual fault locator. With only one compact device, it is possible to check all the necessary parameters for FTTx subscriber network rescue. In addition, Noyes OFL-280 is also a device with high stability, accurate measurement results, friendliness and convenience of a common otdr. With outstanding advantages, Noyes OFL-280 deserves to be considered as a typical device for FTTx network testing.
Please contact us for more detailed information.
Hotline: 0913.532.536 - 0913.620.622
Email: info@vientam.vn
Feature
Typical features of Noyes OFL-280
- Dead zone: 0.8 m, attenuate dead zone: 4.5m
- Dynamic Range: 32/34dB, Wavelength: 1310/1550/1490/1625 nm
- Integrate 4 functions in one product: otdr, power meter, light sources, Visual fault locator.
- Features live fiber measurement, PON network capacity measurement, FTTx fault locator
- Compact, portable, weight only: 0.8 kg
Typical applications
- Check the construction of Core, metro or FTTx networks
- Test cold or live fiber with high resolution, accuracy
- Quick detection of soldering or joining points
- Used for measuring attenuation, link loss, power
- Identify faults via Visual fault locator
- Optical tracing via function Fiber tracing and identification
Specifications
Function OTDR
|
Light emitter type:
|
Laser
|
Safety standards:
|
Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
|
Fiber Type:
|
Single-mode
|
Working Wavelength:
|
1310/1490/1550/1625 nm
|
Wavelength shift:
|
±20/±20/±20/±10 nm
|
Dynamic range: (SNR=1)
|
34/32/32/30 dB
|
Event Dead Zone 1
|
0.8 m
|
Attenuation Dead Zone 2
|
3.5 m
|
Pulse Width:
|
5, 10, 30, 100, 300 ns, 1, 3, 10 μs
|
Distance measuring range:
|
250 m to 240 km
|
Data point:
|
To 30,000
|
Data point range:
|
5.0 cm (range 1.5 km)
|
Group Index of Refraction (GIR)
|
1.4000 to 1.6000
|
Distance measurement accuracy (m)
|
± (1 + 0.005% x distance + data point spacing)
|
Measurement result file format:
|
Bellcore GR-196 V.1.1
|
Memory:
|
Internal memory (>1000 traces)
|
Connect to PC
|
USB cable
|
PON OTDR Modes
|
FTTx - PON Construction, FTTx - In Service
|
Standard OTDR Modes
|
Full Auto, Expert, Real Time
|
OpticalPower Meter
|
Calibrated Wavelengths
|
1310, 1490, 1550, 1625, 1650 nm
|
Detector Type
|
InGaAs
|
Measurement Range
|
+23 to – 50 dBm
|
Tone Detect Range
|
+3 to -35 dBm
|
Wavelength ID Range
|
+3 to -35 dBm
|
Accuracy 1
|
± 0.25 dB
|
Resolution
|
0.01 dB
|
Measurement Units
|
dB, dBm or Watts
|
Laser Source
|
Emitter Type
|
Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
|
Fiber Type
|
Single-mode
|
Available Wavelengths (nm)
|
1310, 1490, 1550
|
Wavelength Tolerance
|
± 20 nm
|
Spectral Width (FWHM)
|
2 nm (maximum)
|
Internal Modulation
|
1 kHz, 2 kHz, CW
|
Wavelength ID (one, two, or three wavelengths)
|
Compatible with Noyes Optical Power Meters and Light Sources
|
Output Power Stability
|
0.25 dB
|
Output Power
|
0 dBm
|
VisualFault Locator
|
Emitter Type
|
Laser
|
Safety Class
|
Class II FDA 21 CFR 1040.10 and 1040.11,IEC 60825-1: 2007-03
|
Wavelength
|
650 nm
|
Output Power (nominal)
|
0.8 mW into single-mode fiber
|